Stability and structural integrity

Integral stability is provided by bracing or other structures, such as concrete cores, integrated with lightweight steel frames. Structural Integrity or robustness can be achieved through multiple interconnections between light-weight steel members. The connection is designed to provide the required binding capability between the different components of the structure.

Cladding

You can use a variety of claddings, such as:

Brickwork

Rain screen

Metallic

Insulation rendering

Sheet metal.

Lightweight cladding usually requires sheathing, which increases the shear strength of the wall.

ACOUSTICAL performance

The floor and ceiling and partition walls provide excellent air transmission and impact sound reduction. Air-borne noise has been reduced by more than 52 DB (with low-frequency correction factor) and by 5 to 10 DB less than that required by section e of the building code. The transmission of impact sound is also very low (< 30DB). Concrete screeds can be introduced to improve the soundproofing, although this will add weight to the floor.

INSULATING LAYER

Thermal insulation is characterized by a heat loss per square meter (u value) of the facade. A low U value of less than 0.2 w/m 2 ° C can be achieved by placing 70 to 100 mm thick insulating plates outside the light steel structure and adding mineral wool between sections C. Where feasible, excellent airtightness can be achieved through an external sheathing plate or an internal diaphragm.

Fire Resistance

Fire protection is provided by multi-layer fire protection panels (BS EN 520 type F). For load-bearing walls, the 90-minute fire resistance of BS EN 1365 is achieved by two inner layers of 15-mm-thick fire-resistant plasterboard with 100-mm-thick mineral wool between layers C. For Jo seam floors, three layers of 12.5 mm fire-resistant plasterboard achieve 90 min fire resistance.

In the Modular rocket, the internal panels prevent fires between modules. An external sheathing plate and a fire stopper between the modules prevent smoke from passing through the cavity space.

If Masonry faces are to be used, fireproof blocks must be placed in the cavity between the inner plate of the Light Steel Frame and the outer plate of the Masonry.

Join our newsletter

Volutpat vel turpis nulla lorem sed semper. Aliquam sagittis sem libero viverra vehicula nullam ut nisl.

Field hospital

30 beds Hospital

150 beds Hospital

300 beds Hospital

Anti epidemic Machine

Laboratory Unit

Laboratory Unit

Emergency Room

Water and electricity

WC

Pharmacy Unit Sterilization Unit Medical Gas Unit

Patient Ward